Comm Port Redirector
On the server, configure the connection for a raw TCP connection to the port that is specified
in the Service Setup screen. See the documentation or tech tip for your server to find out how
to set up an outbound raw TCP connect.
5.3.7 Silent Mode
Check the "Silent" checkbox to suppress the popup window messages from the Redirector.
This option will not take effect until you click "Save."
5.3.8 TCP Keepalive
Click the Advanced button to display the Advanced Settings dialog box.
The TCP keepalive time specifies how long to wait on an idle connection before the PC starts
sending keepalive packets. A keepalive packet is a packet sent to the server to see if it is still
alive. If the server responds then the keepalive timer is reset. If it does not respond then the
PC resends the packet several times at short intervals. After a certain number of non-
responses, the connection is timed out. At this point the connection is either closed or auto
reconnected.
There are two important things to note:
1. This setting is global to the PC, so anything which enables TCP keepalives will use this
setting.
2. The timeout is specified in milliseconds. 1 second = 1000 milliseconds, so if you want a
timeout of 1 minute, the value needs to be 60000. The default Windows timeout value is
7,200,000 (2 hours).