Lantronix XPort User Manual Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 57
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
4: Using Setup Mode for Configuration
XPort™ User Guide 22
3. To enter the Setup Mode, press Enter within 5 seconds. The configuration
settings display, followed by the setup menu options.
Figure 4-2 Setup Menu Options
Change Setup:
0 Server configuration
1 Channel 1 configuration
3 E-mail settings
5 Expert settings
6 Security
7 Factory defaults
8 Exit without save
9 Save and exit Your choice
?
4. Select an option on the menu by entering the number of the option in the Your
choice ? field and pressing Enter.
5. To enter a value for a parameter, type the value and press Enter, or to confirm a
current value, just press Enter.
6. When you are finished, save the new configurations (option 9). The unit reboots.
Using the Serial Port
To initially configure the unit through a serial connection:
1. Connect a console terminal or PC running a terminal emulation program to your
unit's serial port. The default serial port settings are 9600 baud, 8 bits, no parity,
1-stop bit, no-flow control.
2. To enter Setup Mode, reset the unit, either by pushing the red reset button, or
cycling the unit's power (power off and back on). The self-test will begin. You
have one second to enter three lowercase x characters (xxx).
Note: The easiest way to enter Setup Mode is to hold down the x key at
the terminal (or emulation) while resetting the unit.
3. At this point, the screen display is the same as when you use a Telnet
connection. To continue, go to step 4 in Using a Telnet Connection on page 21.
The following figure shows all of the configuration parameters. The remainder of this
chapter describes each parameter in detail.
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 56 57

Comments to this Manuals

No comments